This is your Services Page. It's a great opportunity to provide information about the services you provide. Double click on the text box to start editing your content and make sure to add all the relevant details you want to share with site visitors. Whether you're offering multiple services, courses or programs, you can edit this space to fit your website's needs. Simply double click on this section to open the content manager and modify the content. Explain what each item entails and add photos or videos for even more engagement.
CV Manufacturers | Model Number | Specifications |
|---|---|---|
For faster scanning, we recommend the Reference 620�or Reference 3000/3000AE(EIS Frequency Range: 10 �Hz � 20 kHz) | ||
EIS Frequency Range (with FRA32M module): 10 �Hz � 1 MHz | ||
Current Ranges: 500 mA down to 10 nA (standard); ultra-low current (ULC) option down to ~1 pA (76 aA resolution) EIS Frequency Range: 10 �Hz � 7 MHz (3% / 3� accuracy); high precision up to ~3 MHz | ||
EIS Frequency Range (FRA module): 10 �Hz to 100 kHz (F1 version); upgradeable to 10 �Hz to 1 MHz (F2 version) Electrometer Bandwidth: 1 MHz | ||
Gamry Instruments | PTC 0520E | Potentiostat/Galvanostat: Yes
Power Supply: 110..240V AC / 50..60 Hz
Dimensions: 19� rack cabinet, 4U height
Cooling: Air
Protection Rating: IP20
Input Voltage Range: -10 V to +10 V
Output Voltage: -5 V to +5 V
Output Current: -20 A to +20 A
Current Ranges: 20 mA, 200 mA, 2 A, 20 A
Sampling: 24-bit ADCs at 1 ksps; 14-bit ADCs up to 20 Msps for EIS
Measurement Resolution: 0.001% of selected range
Accuracy: Voltage ? 0.1% of range + 0.1% of reading; Current ? 0.1% of range + 0.5% of reading
EIS Frequency: 1 mHz to 1 MHz
Connection: USB 2.0
Software: MS Windows compatible, TCP Server, NI LabVIEW drivers |
Gamry Instruments | PTC 0550E | Potentiostat/Galvanostat: Yes
Power Supply: 110..240V AC, 50..60 Hz
Dimensions: 19� rack, 4U height
Cooling: Air
Protection Rating: IP20
Input Voltage Range: -10 V to +10 V
Output Voltage: -5 V to +5 V
Output Current: -50 A to +50 A
Max Internal Power Dissipation: 350 W continuous
Limitation: 50 A for ? 2 V, 35 A for 2..5 V, 500 W peak (for 10 s)
Current Ranges: 20 mA, 200 mA, 2 A, 20 A
Sampling Rates:
24-bit ADCs: 1 ksps internal, 50 sps filtered
14-bit ADCs: Up to 20 Msps for EIS
Measurement Resolution: 0.001% of selected range (? 1 ksps)
Accuracy:
Voltage: ? 0.1% of range + 0.1% of reading
Current: ? 0.1% of range + 0.5% of reading
Acquisition Methods: Various (e.g., chronoamperometry, cyclic voltammetry, EIS)
EIS Frequency: 1 mHz to 1 MHz
EIS Amplitude: 1..1000 mV (up to 10 A for < 1 kHz)
PC Connection: USB 2.0
Software: Compatible with MS Windows, TCP Server, NI LabVIEW drivers |
Gamry Instruments | PTC 1050EW | Potentiostat & Galvanostat: Yes
Power Supply: 110�240V AC / 50�60 Hz
Dimensions: 19� rack cabinet, 4U height
Cooling: Water
Protection Rating: IP20
Electrometer Input Voltage Range: -10 V to +10 V
Compliance / Output Voltage: -10 V to +10 V
Compliance / Output Current: -50 A to +50 A
Current Ranges: 500 mA, 5 A, 20 A, 50 A
Sampling:
24-bit ADCs: 1 ksps internal, 50 sps filtered
14-bit ADCs: up to 20 Msps for EIS
Measurement Resolution: 0.001% of selected range for ? 1 ksps
Accuracy:
Voltage: ? 0.1% of range + 0.1% of reading
Current: ? 0.1% of range + 0.5% of reading
Acquisition Methods: Multiple methods including chronoamperometry, cyclic voltammetry, and impedance spectroscopy
EIS Frequency: 1 mHz to 100 kHz (limited use up to 1 MHz)
EIS Amplitude: 1 to 1000 mV, up to 25 A for < 1 kHz
PC Connection: USB 2.0
Software: For MS Windows, includes TCP Server and NI LabVIEW drivers |
Gamry Instruments | PTC 05100EW | Potentiostat & Galvanostat: Yes
Power Supply: 110-240V AC / 50-60 Hz
Dimensions: 19" rack cabinet, 4U height
Cooling: Water
Protection Rating: IP20
Electrometer Input Voltage Range: -10 V to +10 V
Compliance/Output Voltage: -5 V to +5 V
Compliance/Output Current: -100 A to +100 A
Current Ranges: 4 ranges (500 mA, 5 A, 20 A, 100 A)
Sampling: 24-bit ADCs, 1 ksps internal, 50 sps filtered; 14-bit ADCs, up to 20 Msps for EIS
Measurement Resolution: 0.001% of selected range for ? 1 ksps sampling
Accuracy:
Voltage: ? 0.1% of range + 0.1% of reading
Current: ? 0.1% of range + 0.5% of reading
Acquisition Methods: constant V, I, open circuit, manual control, chronoamperometry, chronopotentiometry, linear sweeps, I/V characteristics, cyclic voltammetry, cyclic amperometry, pulse voltammetry, impedance spectroscopy, programmable sequences.
EIS Frequency: 1 mHz to 100 kHz
EIS Amplitude: 1 to 1000 mV, up to 50 A for < 1 kHz
PC Connection: USB 2.0
Software: MS Windows software, TCP Server, NI LabVIEW drivers. |
Gamry Instruments | MEGA EIS | |
AVL | AVL X-ion , AVL Smart EIS | |
PalmSens | PalmSens4 | General
Configuration: PS4.F#.05, PS4.F#.10
DC-potential range: �5 V, �10 V
Compliance voltage: �10 V
Maximum current: �30 mA (typical)
Potentiostat (controlled potential mode)
Applied dc-potential resolution: 76.3 �V (18-bit)
Applied potential accuracy: ?0.1% �1 mV offset
Current ranges: 100 pA to 10 mA (9 ranges)
Current accuracy: < 0.2% of current �10 pA �0.1% of range
Measured current resolution: 0.005 % of current range (18-bit, 5 fA on 100 pA range), 0.0025% of 10 mA range
Galvanostat (controlled current mode)
Current ranges: 1 nA to 10 mA (8 ranges)
Applied dc-current: �6 times applied current range
Applied dc-current resolution: 0.0076% of applied current range (<10 mA), 0.0038% of 10 mA range
Applied dc-current accuracy: < 0.2% of current �10 pA �0.1% of range
Potential ranges: 10 mV, 100 mV, 1 V
Measured dc-potential resolution: 78.13 ?V at �10 V, 7.813 ?V at �1 V, 0.7813 ?V at �0.1 V
Measured dc-potential accuracy: ? 0.05% or �1 mV (for |E| < �9 V), ? 0.2% (for |E| ? �9 V)
FRA / EIS (impedance measurements)
Configuration: PS4.F0.##, PS4.F1.##
Frequency range: 10 ?Hz to 100 kHz, 10 ?Hz to 1 MHz
AC-amplitude range: 1 mV to 0.25 V rms, or 0.7 V p-p |
PalmSens | MultiEM4 LR | Potential range: �3 V
Max. compliance voltage: �5 V
Current ranges: 1 nA to 10 mA (8 ranges)
Max. current: �30 mA
Electrode connections: WE, RE, CE and ground, 2 mm banana plugs
Hardware options: EIS up to 200 kHz, Galvanic Isolation
dc-potential range: �3 V
compliance voltage: �5 V
maximum current: �30 mA
max. data acquisition rate 1 000 000 samples /s
applied potential resolution: 100 �V
applied potential accuracy: ? 0.2% �1 mV offset
current ranges: 1 nA to 10 mA, 8 ranges
measured current resolution: 0.009% of CR (92 fA on 1 nA range)
measured current accuracy: < 0.2% of current �20 pA �0.2% of range
bandwidth settings: 320 Hz, 3.2 kHz, 30 kHz or 570 kHz |
PalmSens | MultiPalmSens4 HR | Potential range: �6 V
Max. compliance voltage: �8 V
Current ranges: 100 nA to 100 mA (7 ranges)
Max. current: �200 mA
Electrode connections: WE, RE, CE, Sense, and ground, 2 mm banana plugs
Hardware options: EIS up to 200 kHz, Galvanic Isolation
dc-potential range: �6 V
compliance voltage: �8 V
maximum current: �200 mA
max. data acquisition rate 1 000 000 samples /s
applied potential resolution: 183 �V
applied potential accuracy: ? 0.2% �1 mV offset
current ranges: 100 nA to 100 mA 7 ranges
measured current resolution: 0.009% of CR (9.2 pA on 100 nA range)
measured current accuracy: < 0.2% of current �0.2% of range
bandwidth settings: 320 Hz, 3.2 kHz, 30 kHz or 570 kHz |
PalmSens | Nexus | General:potential range �10 V
compliance voltage �12 V
maximum current �1.1 A
impedance analyzer 10 �Hz to 1 MHz
sample connections WE, WE2, S, S2, RE, CE, GND
Potentiostat:
applied dc-potential resolution 78 �V
applied potential accuracy ?0.1% �1 mV offset
current ranges 100 pA to 1 A (11 ranges)
maximum measured current �1.1 times CR for 1 A range, �4.5 times CR for 10 mA range, �5 times CR for all other ranges
measured current accuracy < 0.1% of value �10 pA (bias) �0.1% of range (offset)
measured current resolution 0.0038% of CR (3.8 fA on 100 pA range)
Galvanostat:
current ranges 1 nA to 1 A (10 ranges)
applied dc-current �1.1 times CR for 1 A range, �4.5 times CR for 10 mA range, �5 times CR for all other ranges
applied dc-current resolution 0.0038% of applied current range
applied dc-current accuracy < 0.1% of current �10 pA (bias) �0.1% of range (offset)
potential ranges 10 mV, 100 mV, 1 V
measured dc-potential resolution 78 �V at �10 V (1 V range), 7.8 �V at �1 V (100 mV range), 0.78 �V at �0.1 V (10 mV range), 78 nV at �0.01 V (1 mV range)
measured dc-potential accuracy < 0.05% of value �1 mV (offset) |
Novocontrol Technologies | NEISYS | |
Zurich Instruments | MFIA , MFITF | |
Hioki | IM7587 , IM7581, IM7580A, IM7585, IM7583, | |